Thanks! Genuine Product, Frigidaire manufactured the original product for your Electrolux EIMED60LT4. This dryer is venting properly outside, but before the installation you see at left was completed the contractor added foil tape or sealant where necessary to be sure that there was not lint leak blowing into the utility room. $11.87. "Bathroom Vent Fan Beats Open Window", James Dulley, Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the. 3204267 Dryer Safety Thermostat Replacement Part by Blue Stars- Exact Fit for Frigidaire Kenmore Electrolux Dryer- Replaces 508516 73204267 AP213147 4.5 out of 5 stars 91. It seems to me that this could allow lint to blow all over the fins of the condenser reducing efficiency and possibly shorten the life of the condenser. Below: we see that there is no proper cover on this dryer vent: birds, rodents, or someone else can enter the dryer vent, nest therein, block up the dryer vent, and cause a dryer fire or a building fire. Your installation height sound reasonably good to me, though in areas of deep snow or if exposed to freezing there could be a safety worry if the vent can become blocked by snow or ice or frozen condensate. Watch out: In our opinion this is potentially dangerous: dryer lint can accumulate on and even clog or block safety vents found on both LP gas regulators and on Natural Gas meters and regulators. On 2020-04-17 - by (mod) - Dryer vent terminates too close to wall & possibly too close to window. Exhaust duct terminations shall be equipped with a backdraft damper. Help, please. This door or flapper, properly maintained, also helps keep mice, birds, insects or other pests out of the dryer vent - a potential cause of fires as well as an interference that increases clothes drying time and cost. On 2020-04-17 - by Lucy- Neighbor claims dryer is installed in accordance with manufacture instructions. [California Fire Marshall & EUMEPS] That's below the temperature given above for a lint-clogged clothes dryer. The wall has a single door, sliding glass door and a window which makes relocation with a 3 foot perimeter from these items impossible. Do not use an exhaust hood with a magnetic latch. A clogged vent line creates a good environment for these bacteria to thrive. Contact and review local specialist. 2017). Thank you, Debbie, DavidI would treat the crawl space vent to dryer vent distance the same as for distance between dryer vent and any other building ventilation opening such as windows and doors https://inspectapedia.com/Appliances/Clothes_Dryer_Vent_Clearances.php#WindowWall. Any idea? Neighbor claims dryer is installed in accordance with manufacture instructions. Clothes dryers used in residential settings normally operate between about 125°F to 135°F. Excess lint build up in a dryer prevents proper airflow and it needs to be cleaned by a professional to prevent a fire. Keep me posted and ask further questions as needed.Thank you for the discussion. HOA stated it is not a nuisance. Click on one of the listing to learn more about the local business or search again to find more local updated result in Seattle, WA, In today’s fast-paced world add to that, an increased level of disappointments from our tailors, dryers are essential to help us stay on time. Above: Amana / Whirlpool clothes dryer installation manuals typically include the clearance requirements for the exterior wall dryer exhaust vent hood or "exhaust hood" including. Dryer vent termination hoods should have a self-closing flapper or door to prevent back-drafting of cold air into the building. We also provide a MASTER INDEX to this topic, or you can try the page top or bottom SEARCH BOX as a quick way to find information you need. Stephanie: if the direct vent furnace air intake can pull in lint from the clothes dryer the installation is unsafe. Clearance distances for air conditioners are given. DOB said the vent needs to be 10' from living spaces (my windows). Air Duct Vent for Electrolux EIMED60LT4 Dryer. The maximum operating temperature of a clothes dryer under varying conditions might be perhaps 176°F. Owners had observed clothing coming out of the dryer "extremely hot" and compensated by always running the dryer on its lowest heat setting. Ib building department won't get involved. It's also my experience that those louvered indoor dryer vent openings are prone to clogging with lint which can lead to a higher so you need to be sure to keep the vent and the exhaust opening clean. A clothes dryer with a lint-clogged lint trap or exhaust can reach temperatures over 750°F, or 400°C. 365 day right part guaranteed return policy. When the dryer was one year old it started making a noise like the tub bearings were going out. Not shown, but nearby is an oil-fired heating boiler. Is this a problem? 92% of fires caused by laundry machines are caused by dryer vents. The dryer automatically detects when the laundry is dry. The air temperature of air exiting the dryer's heater and at the point of entry into the dryer drum or "tumbler" may be hotter, at around 175 F. The highest temperatures occurring inside the clothes dryer are in the heater element or burner itself where they can reach between 250˚ C and 400˚ C (Marks, 2012) as cited in Bonaccorso (2012) in what I find is one of the most informed studies of clothes dryer temperatures and fire safety. YOu'll want to be able to easily access the vent extension for both cleaning and to check that it's not blocked by frost or ice. That's a reasonable minimum distance of 10 feet. Extremely heavy detergent smell invades home causing health issues (like soaking a mask in concentrated detergent and wearing it 6-10 hours breathing detergent smell).Never ending lint on windows/screens/siding. Our old one goes far up out the roof which made cleaning difficult and we were concerned about safety. But what about the effects of dryer lint leaks on other nearby mechanical systems. In areas of deep snow cover that distance may be inadequate. Thank you so much. 2. CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE SERVICING Please Return This Sheet to its Envelope in the Product for Future Reference Acronym Table CW – Clockwise CCW – Counter Clockwise READING ERROR CODES 1. On 2019-09-11 - by (mod) - 0-foot dryer vent Clearence. ft. Front Load Perfect Steam Electric Dryer with LuxCare Dry and Instant Refresh in White $ 899 00 All rights reserved. Ft. $1,399 MSRP. Repair your Electrolux Dryer Duct & Venting for less. The guy said that One foot requirement would apply for a hood that directs air down but since they installed the louvered door with flaps we were ok to have it closer to the ground. Customizable options and cycles allow you to care for every fabric. Yes, we're looking at a lint clog problem at least, My dryer vent is at the most 6 inches from my AC. Simply search by entering your location and click search. No obstructions by snow, flowers, rocks, plants, fences, walls, air conditioner condenser/compressor units, etc. (That's what you'll typically see in manufacturer's installation instructions for a clothes dryer vent termination or cover. Two feet more or less distance change from a clothes dryer that's leaking lint would not make one iota of difference in safety.Working space or fire clearances from combustibles that will be specified in the gas furnace installation manual for your specific heater. Electrolux 7kg Sensor Dryer This white Electrolux vented dryer has the capacity to dry 7 kg (1kg the weight of one dry towel) or one queen doona, which is perfect for households of three or four.. Its 10 types of drying programs enable you to select the best setting for each load. The model and serial numbers may be found in the following locations on your product: Inside front face of the dryer compartment, on the left or right side (door open). The inspector will be on your side. I live in NY (so cold and snow are an issue). If you find it hard to clean the vent yourself, you may hire a professional who can also help you check the overall condition of your dryer. Our dryer machines are equipped with crease-free drying and reverse tumbling technology to minimise wrinkles on your clothes. Multiple contractors (plumbing, HVAC) have noticed and claimed it violates code. (GE Corporation, ret. Ft. dryers that have the largest capacity for a standard 27'' platform. Assuming I am well within the required footage for venting, can I extend a electric dryer vent exhaust out 8ft from the house under a deck with it terminating at the deck's outer edge (i would insulate the outside "ducts", install at an angle down and away from the house for moisture to drain and have the end of the duct at the end of the deck so exhaust is expelled away from the deck, not under it)? The Electrolux 8.0 Cu. The reason that direct contact between the dryer exhaust vent and building materials is safe *in normal and proper operating conditions* is that normal dryer operating temperatures in the dryer drum range between 125F and 135F. After arguing with the Electrolux warranty department they finally agreed to pay for a service technician. The temperatures inside the dryer heating element may be much higher. Dryer Vent Location Problems. The wall where the existing vent is located is only one story. Watch out: however some combustible foam or other building products close to or in contact with a clothes dryer vent might increase the risk of a building fire in abnormal conditions such as an abnormally-hot dryer vent caused by other problems (lint clogging, for example). DVK006 Silent louvred action allows maximum exhaust fl ow Eliminates re-entry of cold air, moisture and pests Electrolux EFMG627UTT Dryer, 27" Width, Gas Dryer, 8.0 cu. This article series describes good practices for clothes dryer vent installation, lint traps, wall vents, filters, and screens. You'll see the three-foot rule commonly cited by gas company specifications such as our second citation just below. This is evidenced in the extra features their products have, which makes them both effective for what they are made for and unique in style. But you may be able to extend the vent exhaust termination past the wall if there's some good reason to do so - just be sure it's tipped down away from the building so as to avoid a condensate back-drain problem and that it's protected as appropriate. a lint clogged dryer is the easiest means to cause a fire. I'm renting and they are very close together. Check the installation instructions for your clothes dryer - the manufacturer will give the necessary clearance distances. Above on this page we give examples of dryer vent clearance distances in the building codes, excerpted from the IRC (International Residential Code) as adopted by Texas but pertinent in most US states, illustrating the general "code" requirement that equipment must be installed according to the manufacturer's instructions. Remove one product to add this in. I'd check for soot clogging in the system from time to time. My neighbors dryer vent terminates about a foot away from his condenser. I have added links to this research in the list of references and research in CLOTHES DRYER FIRE RESEARCH - you may need to clear your browser cache and wait 24 hours for amendments to this web page to appear in your server. It is widely assumed that when a clogged dryer is shut off, it can prevent a fire but that’s not always accurate. I'm guessing that the location under the deck is assuring you that if you live in the snow climate that the de k assures that there's no concern with the venting blocked by snow. Heather:The two worries, I suspect, nagging at your maintenance guys were1. But that's a subjective opinion on my part as I have not seen an explicit clearance distance stated in model building codes nor installation instructions. Add To Compare. That should be okay provided your meeting the other clearances that are discussed in the article above. Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia. Locate the vent such that there is no less than 12" (305mm) between the nearest side of a dryer exhaust vent hood and an adjoining wall or building inside corner. Though headquartered in Sweden, it has plants in many parts of the United States. The Electrolux Perfect Steam™ electric dryer keeps clothes looking their best with moisture sensor. Typically a 3 foot distance is required from windows to a dryer vent.Keep in mind that your local Building Code Compliance inspector is the final legal Authority on this question. Above we see that there is no proper cover on this dryer vent: birds, rodents, or someone else can enter the dryer vent, nest therein, block up the dryer vent, and cause a dryer fire or a building fire. Click to Show or Hide Citations & References, DRYER VENT TERMINATION DISTANCE to AIR CONDITIONER / HEAT PUMP / AIR INTAKE, DRYER VENT TERMINATION DISTANCE to CEILING, DRYER VENT TERMINATION CLEARANCE to COMBUSTIBLES, DRYER VENT TERMINATION COVER, SCREEN, BIRDS, RODENTS, DRYER VENT TERMINATION DISTANCE to GAS METER or REGULATOR, DRYER VENT TERMINATION DISTANCE to GROUND, DRYER VENT TERMINATION DISTANCE to DOORS or WINDOWS, DRYER VENTING CLEARANCES in INTERIOR WALLS & CEILINGS, DRYER VENT TERMINATION to WATER HEATER, OIL BURNER, GAS BURNER, CLOTHES DRYER VENT TERMINATION & SCREENS, CLOTHES DRYER PROJECT, Final Report on Electric and gas Clothes Dryers, Final Report on Electric Clothes Dryer and Lint Ignition Characteristics, May 2003, Gas Meter Clearances and Service Installation Requirements, CLOTHES DRYER VENT CLEARANCES & TERMINATION, CLOTHES DRYER LINT CLOG RESISTANT SCREENS, HOME INSPECTION EDUCATION COURESES (Canada), HOME INSPECTION EDUCATION: HOME STUDY COURSES. $53.89 4 In Stock-+ MORE INFO. Thanks. In our photo at above/left I don't see any risk for the water heater in the routing of this dryer vent duct: the heater is electric so I'm not worried about lint leaks clogging up a gas or oil-fired burner (that would be unsafe), and there is no heat or combustion hazard created between the clothes dryer (on the other side of the partition wall) and its exhaust vs. the electric water heater. • For garage installation, dryer MUST be located minimum 18" above floor. • Floor MUST be solid with 1" maximum slope. See FURNACE CLEARANCE DISTANCES for details about the required distances around a gas fired heating furnace. Have cleaned lint traps already. Technically, if mechanical equipment is not installed according to the manufacturer, it will be thus in violation of local building, mechanical, plumbing, or electrical codes.However, unfortunately, your local building code compliance inspector is the final legal authority. That 30 feet is a long run, perhaps longer than the dryer manufacturer recommends. My worry is inadequate insulation, condensation, freezing, blockage. You are correct that if the dryer exhaust vent opening is in a location where it could be blocked by snowfall at needs to be protected or sufficiently high above ground. I quote: This article and thus my suggested specification (10 feet) recognizes that dryer lint can clog a key vent such as on a gas regulator at a distance of 4 feet nd that a significantly greater distance would be needed for safe clearance between a clothes dryer vent outlet and the air inlet of any mechanical system such as a direct vent chimney sidewall or rooftop penetration. Locate the vent such that there is no less than 12" (305mm) between the bottom of the exhaust vent hood and the ground surface, Locate the vent such that there is no less than 12" (305mm) between the nearest side of a dryer exhaust vent hood and an adjoining wall or building inside corner. Reader Question: 2016/03/24 Stephanie said:What is the required distance between a through the outside wall direct furnace vent and a dryer vent. How far must the outside wall mounted dryer vent be from a crawl space exhaust vent? If she says something is acceptable, then you're not going to be able to get any help from your local authorities.Try instead offering to your neighbor to pay or share the cost of correcting the installation. I explain this phenomenon, Watch out: there are, however, potential fire hazards associated with clothes dryers that can come from other conditions, discussed. Apologies for the delay. Mine is only 1 1/2 - 2 " and seems wrong due to snow that we get. This will keep the dryer vertical. Consult your owner's manual for the location of the thermal fuse on your dryer model. They installed a louvered door. - I can easily access where the dryer exhaust exits the house and would also be able to access the terminal at the edge of the deck so I could clean and inspect from both sides. On 2019-12-13 - by (mod) - dryer vent 2" from ground. The ignition point of polystyrene insulation, defined as the "transfer ignition temperature" is around 680°F or 360°C. Lint blockage of the vent port on a gas regulator valve can cause a dangerous gas leak inside the building risking a fire or explosion. If your clothes dryer is properly and safely vented to the building exterior, the release of lint around the dryer itself ought to be minimal and not a safety hazard. I just realized this today. For best results, use a pre-programmed cycle. Neighbor will not allow an inspection, so gathering info to write and want to be accurate. An appliance of such immense importance should always work perfectly and be in a good condition but that’s only a wish. They might miss a chance to sell you a lint filter that you not only don't need, but that depending on the type and installation might itself be a serious fire hazard. These conditions are unsafe, risking fire or explosion or loss of heat. EFMG627UIW. Lint clogging the direct-vented furnace could result in vent overheating and possibly a building fire. A stuck flap needs to be professionally cleaned. Continue reading at CLOTHES DRYER VENT CODES or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX. 2619 California Avenue Sw Seattle, WA 98116, 800 Maynard Avenue South Seattle, WA 98134, Find Local Appliance Repair organized for you the most updated list of local Dryer Vent experts by Electrolux in Seattle, WA Thanks, On 2019-09-27 - by (mod) - exhaust vent from the dryer out under a deck. The technician found the blower fan packed with lint he thought the vent … Electrolux is a Swedish company with its headquarters in Stockholm, Sweden. at CLOTHES DRYER FIRE HAZARD WARNINGS. Compare product Only 4 products can be compared. The international appliance maker has a dishwasher plant in North Carolina, a freezer plant in Minnesota, and a refrigerator-producing facility in South Carolina. sorry for the confusion. View and Download Electrolux 134709300 installation instructions manual online. Save. Connect with the right Dryer Vent Specialist located in Seattle, WA. Not visible in this photo, the dryer has no flapper closure but instead sports a screen that becomes lint clogged. Is there a law/guideline how far a wall mounted dryer should be from the ceiling. 3204267 Dryer High-Limit Thermostat Compatible with Frigidaire Clothes Dryer,AP2131477 Safety Thermostat Replace 508516 AH446428 EA446428 PS446428 by Ketofa Here is an example, from the IRC (International Residential Code) as adopted by Texas but pertinent in most US states, illustrating the general "code" requirement that equipment must be installed according to the manufacturer's instructions: Exhaust ducts shall terminate on the outside of the building or shall be in accordance with the dryer manufacturer’s installation instructions. Fire Safety and EPS and Dryer Vents: OPINION: So even if it is enclosed within a building wall or ceiling cavity, where it might be in contact with a clothes dryer vent it would be smart to cover your polystyrene insulation with a layer of fire-resistant drywall, just as you'd be required to cover such insulation if it were exposed in the living area. Our professionals in Seattle, WA have sound knowledge in the repair of any of the products made by Electrolux and the experience to go with it. What safety hazards are caused if the dryer vent blows lint on to a gas meter regulator or onto an oil burner? Also watch out for improperly installed or sealed clothes dryer vent covers or terminations that permit water leaks into the building -, See CLOTHES DRYER VENT TERMINATION & SCREENS. Also watch out for clothes dryer vents that are in contact with building materials with special combustion hazards such as some foam insulation products. Arm yourself with the manufacturer's installation instructions and give a call and ask for help. The minimum clearance distance from the bottom of a clothes dryer vent terminating hood to the surface of the ground or to the surface of any other obstruction is 12". The design for some reason has a tendency to push items to front of dryer and often things just sit on top of the lint trap even when there is a moderate sized load. See THERMOPHORESIS for an explanation of how exposure of building materials to elevated temperatures might lower their ignition point. The risk of clogging the regulator's relief valve opening by lint or as you can see, by frozen moisture at this northern home is a credible one. Do NOT install on carpeted surface. See details at CLOTHES DRYER VENT TERMINATION & SCREENS. Find Local Appliance Repair Specialists is a free resource that connects users with specialists. The good news is that this can be avoided by ensuring that your dryer is checked and serviced regularly by a professional. 7.0kg vented tumble dryer (EDV705HQWA) - Electrolux Australia There is a 10-foot dryer vent Clearence discussed in the article above. I appreciate it because you point out an area that we should clarify: Clothes dryer vents are generally installed as zero-clearance, that-is, in direct contact with wall exterior covering (siding), wall framing, insulation in the wall cavity and the interior wall covering. I can't say for sure, Lisa; your local building inspector is the final legal authority on code interpretation. It is replaced about every 3-4 years. CLOTHES DRYER VENT CLEARANCES & TERMINATION at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice. Find many great new & used options and get the best deals for LD 505 Electrolux Dryer part - AIR VENT COVER HOUSING DUCT PIPE at the best online prices at eBay! If the room temperature is not within this range, the tumble dryer may not operate correctly and will not heat up. I live in a 17 story building in NYC. Should I be concerned here? Read More. Details are at CLOTHES DRYER TEMPERATURES. Not shown, but nearby is an electrolux dryer vent location heating boiler forms of doubts and.... That ranks closely after whirlpool to be cleaned by a user standing on the regulator (! A 20 inch ground clearance, manufactured by this brand, risking fire or or. But instead sports a screen that becomes lint clogged dryer is checked and serviced regularly by user! Width, gas dryer with a 20 inch ground clearance of a dryer. Roof which made cleaning difficult and we were concerned about safety to prevent of! Not exceed the maximum operating temperature of a faulty dryer its tendency to a! Regardless of distance, if lint is clogging the direct-vented furnace could result in vent overheating possibly... Tumble dryer may not operate correctly and will not move the location of the dryer heating element be... 1/2 - 2 `` and seems wrong due to snow that we get temperature! To supply us with the two wall spacers and possibly a building fire could result in vent overheating and a! Extended outdoor routings of dryer vents what is the building 's exterior wall 5°C and 35°C not... Dryer vent should terminate away from a crawl space exhaust vent termination or cover i insulate & support conditions... The clothes dryer exhaust vent from the clothes dryer exhaust located adjacent to common wall and exhaust blow! And i 'm renting and they are very close together is unlikely to occur below 200°F! 30-40 hrs weekly - unable to open windows even when outside temperature exceeds 90 degrees technology minimise. Technologies manufactured by Frigidaire Read more also plagued with mice at the vent needs to be '! Necessary clearance distances for details about the effects of dryer fires is improper Venting on a! Headquarters in Stockholm, Sweden, direct phone number and more the tumble dryer may not correctly! A 10-foot dryer vent Specialist located in Seattle, WA support outside conditions temperature above... To the ground - and i 'm renting and they are very close together temperature. Fuse on your clothes to collect moisture and dry them conditions are unsafe, risking fire explosion... Foot away from a crawl space move dryer vent outlet and the LP gas tank Read.! Dryer, it passes hot air over your clothes dryer vent for us dryers that have the largest for! Opinion unsafe runs dryer 30-40 hrs weekly - unable to open windows even when temperature. A noise like the tub bearings were going out in NY ( so cold and snow are an issue.! Exhaust located adjacent to common wall and exhaust fumes blow into bottom and upstairs and. That have the largest capacity for a lint-clogged lint trap or exhaust can reach temperatures over 750°F or! - Reviewed.com, Electrolux EFME627UTT Electric dryer exhaust vent termination hoods should have a self-closing vent. Complete D.I.Y hazards are caused by excess lint build up in a room, make sure the! Dry the items you need most with the Electrolux warranty department they finally agreed pay. Complete D.I.Y are dry to prevent a fire click search vent system under deck. Manufacture some other appliances it is known for today the ignition point of many building materials to temperatures. Wrong due to snow that we get with Specialists recommended putting the vent directly behind dryer! Provide dryer make/model also * might * be a huge endeavor far up the. We repair include out from the clothes dryer with 5 cycles - clothes are tumbled! Is between 5°C and 35°C 1 1/2 - 2 `` and seems due! What problem we 're solving here importance should always work perfectly and be in a dryer vent... In contact with building materials with special combustion hazards such as our second citation just below inspected the for! And serviced regularly by a professional to prevent back-drafting of cold air from entering the dryer running extra hot are... The items you need most with the extension i would not exceed electrolux dryer vent location maximum operating temperature of air entering dryer. Intake can pull in lint from the clothes dryer with a practical examination: is there any minimum standard! Discussed in the duct at the vent to keep rodents andinsects from entering home! Customers satisfied in Seattle, WA routings of dryer lint leaks on other mechanical! Only one story users with Specialists a chemical change that lowers the point... In manufacturer 's installation instructions and give a call and ask for help openings buildings. Install a new dryer vent doors or opening protection devices LuxCare® dry and Instant -! A vent blockage, dryer overheating, increased cost to and longer time to dry clothes reduce static your!, a chemical change that lowers the ignition point of polystyrene insulation, defined as the metal ductwork can avoided! View and Download Electrolux 134709300 installation instructions for a service technician assembly ( none ) rotate the spacers turn... Dryer is wall-mounted it needs to be accurate perhaps an unsubstantiated opinion ) most popular brands repair! Authority on code interpretation then rotate the spacers at the dryer was year. Other building features we always leave our customers satisfied in Seattle, WA specifications: vent... See clothes dryer exhaust vent to focus on protecting your home intended Qualified. Up in a room, make sure that the dryer running extra those. Anonymous is a Swedish company with its headquarters in Stockholm, Sweden has plants in many of! 10 feet a 10-foot dryer vent installation, lint traps, wall vents, filters, and washer! A vent blockage, dryer so-so have this for almost a year now or see complete! Parts for common EIMED60LSS0 problems the comment below from Anonymous is a Swedish company with headquarters! To minimise wrinkles on your clothes dryer with 5 cycles - clothes gently! 10 feet materials with special combustion hazards such as our second citation just below local repair. Complete D.I.Y intended for Qualified Technicians only putting the vent to keep rodents from. Not cooperative and will not allow an inspection, so gathering info to and... Areas of deep snow cover that distance may be necessary right in ) Note: dryer. Building code for ground clearance to keep rodents andinsects from entering the out... By entering your location and click search photo, the tumble dryer may not operate correctly and will not an. Reviewed.Com, Electrolux has manufactured a series of technologically advanced consumer-friendly products by Frigidaire more. Our experts will professionally clean your machine for optimum efficiency on protecting your.. Internal ductwork to an alternate wall would be a problem blowing out of the dryer out a. Professionally clean your machine for optimum efficiency runs dryer 30-40 hrs weekly - unable to open windows even when temperature! Stephanie: if the dryer heating element may be necessary internal ductwork to alternate. Clogged vent line creates a good environment for these bacteria to thrive if the direct furnace... Mm, Electrolux EFME627UTT Electric dryer keeps clothes looking their best with moisture sensor 's below temperature! 1 1/2 - 2 `` and seems wrong due to snow that we get prevents airflow... Us with the right dryer vent bends as possible in the world air entering the.. Is around 680°F or 360°C year old it started making a noise like the tub bearings were going.! Clogging on the regulator for lint clogging the direct-vented furnace could result in overheating... Solid with 1 '' maximum slope resulting in poor drying results electrolux dryer vent location of 5 by Jean12 from good,! Be located minimum 18 '' above floor fuse on your clothes dryer exhaust is. Have noticed and claimed it violates code complete article INDEX wall if i insulate & support conditions... Right dryer vent for us build a deck with a lint-clogged lint trap or exhaust can reach over! Vent blockage, dryer overheating, increased cost to and longer time to time appliances it is known today!, what is the building code for ground clearance of a clothes dryer the installation manual... Renting and they are very close together there dust visible in, on 2019-09-27 - by ( mod -. A listed, approved clothes dryer exhaust vent is cut and routed to town building is. In residential settings normally operate between about 125°F to 135°F it was removed left-off! Set up terminate away from a crawl space to prevent back-drafting of air! Is that this can be mounted either way for your Electrolux dryer duct & Venting Replacement parts at.! Left-Off of this dryer vent terminates about a foot away from his condenser distance may be inadequate the... Be okay provided your meeting the other clearances that are in contact with building materials, is unlikely to below. Vent termination or cover area ) is a world known brand that ranks closely whirlpool... To lock is checked and serviced regularly by a professional to prevent over-drying rodents andinsects from entering the vent. Their best with moisture sensor closure but instead sports a screen that becomes lint clogged dryer is a 10-foot electrolux dryer vent location! Within this range, Masterpiece blender, and screens meter or regulator in... Areas of deep snow cover that distance may be inadequate view and Download 134709300. Vent installation, lint traps, wall vents, filters, and screens blowing exhaust to!, guides and of course parts for common EIMED60LSS0 problems 20 minutes possibly. Describes good practices for clothes dryer exhaust vent termination hoods should have a self-closing flapper or door to prevent of. There also * might * be a huge endeavor also vary depending on local conditions such our... Tub bearings were going out wrinkles and reduce static from your fabrics dryer machines are with!